Real-time solar monitoring

Catch every dead string in seconds — not the next morning.

Solarping watches every string, MPPT and inverter across every solar plant you run — and pings your team the instant something fails.

1–2 secfault detection
50+ plantsmonitored live
~90 MWpunder watch
The problem

A failing string can hide for hours — and quietly burn your yield.

Vendor dashboards were built for record-keeping, not for catching faults. The cost shows up on the generation report.

Dashboards refresh slowly

Cloud portals update every 10–15 minutes. A dead string bleeds power long before anyone sees a number change.

No alarm when it matters

A string at 0.00 A just sits in a long table. Nothing flashes, nothing pings — you have to spot it yourself.

Too many sites to watch

One manager, 8–10 plants, hundreds of strings. Watching every dashboard for 10 hours a day is impossible.

Y-string faults stay hidden

When one leg of a paired Y-string fails, the other keeps producing — so the loss looks invisible on aggregate views.

What Solarping catches

String-level intelligence for your whole portfolio.

Solarping reads live data down to every individual string and flags the faults that actually cost you energy.

String drop-out

A string suddenly stops conducting while its peers continue. Caught within seconds, not the next report.

Partial under-output

A string running below its peers — early soiling, connector wear or shading — surfaced before it worsens.

Y-string imbalance

Paired-string layouts where one leg fails while the other masks the loss on aggregate dashboards.

Inverter offline

An inverter that stops reporting during sunlight hours is flagged immediately, not hours later.

Overheating & faults

Insulation drops, thermal derating and ground faults — pre-empted before a shutdown costs you a day.

Underperformance

An inverter quietly lagging its peers' yield is ranked and flagged in plain language every evening.

How it works

From the panel to your pocket — in four steps.

Solarping plugs into the loggers you already have. No new hardware, no portal logins for your team.

STEP 01

Read

Pulls live string, MPPT and inverter data every 1–2 seconds from your existing loggers.

STEP 02

Detect

Smart rules spot the fault — even at single-string level — and filter out dawn/dusk noise.

STEP 03

Alert

Pushes an instant alert to your Telegram group and tags the person who needs to act.

STEP 04

Resolve

Auto-clears the alert when the issue is fixed. Every event is logged for audit.

Coming soon

The Solarping plug-and-play logger.

Today Solarping works with the loggers you already have. Soon, you'll be able to drop in our own purpose-built device — no configuration, no integration project.

  • Connect it to the inverter and power on — it's live in minutes.
  • Auto-discovers strings, MPPTs and inverters on the network.
  • Streams string-level data straight into Solarping — zero setup.
  • Built for sites with older or no compatible logger.

Want early access? Join the waitlist →

Why teams switch

The same fault, found two very different ways.

A string sitting at 0.00 A — here is what each approach does about it.

Vendor cloud dashboard
  • The 0.00 A reading appears only after a 10–15 minute delay
  • No alarm is raised — it just sits in a long table
  • Someone must open every site and scan every string
  • Easy to miss — and every missed fault is lost power
With Solarping
  • The fault is caught within 1–2 seconds of happening
  • An instant alarm lands in your Telegram group
  • The responsible person is tagged automatically
  • Nothing to watch — the alert finds you
Free power-loss calculator

How much are undetected faults costing your plants?

When a string or inverter fault goes unnoticed on a slow dashboard, it quietly drains revenue every hour. Use this free solar power-loss calculator to estimate what real-time detection recovers across your portfolio — then book a pilot to measure it precisely on your own sites.

8sites
2MW
3.5/ kWh
6hrs
4faults
Estimated power you stop losing
4,51,584 / year
≈ ₹37,632 every month · 10,752 kWh recovered monthly
See your real numbers — book a free pilot →

A conservative estimate. Actual recovery depends on your fault profile — a pilot measures it precisely on your own plants.

Proven at scale

Already watching real megawatts, every second.

50+
Solar plants
Monitored live, pan-India
~90
MWp under watch
And scaling
4,000+
Monitoring points
Strings & inverters
1–2s
Detection latency
vs 10–15 min on stock tools
Questions

Everything you need to know.

Solarping detects string, MPPT and inverter faults within 1–2 seconds of them occurring — compared with the 10–15 minute delay typical of vendor cloud dashboards.

Yes. Solarping is logger-agnostic and works with the data loggers and inverters you already have. There is no new hardware to install and no rip-and-replace.

Solarping pushes an instant alert to your Telegram group the moment a fault is detected, tags the responsible person, and auto-clears the alert once the issue is resolved — so the chat only ever shows what is genuinely wrong.

Yes. Solarping is built for portfolios. It monitors every string across every plant simultaneously, so one manager can confidently oversee dozens of sites without watching dashboards all day.

No. Solarping uses sunrise/sunset suppression, wiring-map awareness and debounce logic, so dawn and dusk ramps and unwired positions never trigger noise. You only get pinged for real faults.

A typical pilot goes live in under a week: we connect to your existing logger, map your plant, tune thresholds, and set up your Telegram group. The first plant is free to pilot.

Get started

Hear your plants — before they go dark.

Start with a free pilot on a single plant. If Solarping doesn't catch a fault you'd have missed, you walk away. Most pilots go live in under a week.

Contact us
Request your free pilot →

We typically reply within one business day.